Scale: None Size: 77 x 133 Drawing entitled General arrangement of reactor unit. Transverse elevation.
Scale: Half full size Size: 77 x 133 Drawing entitled Section through bottom of reflector brick and support plate of reactor.
Scale: 1/8" to 1 ft Size: 77 x 133 Drawing entitled General arrangement of circulating water. Pump house.
Scale: None Size: 76 x 111 Drawing entitled Oldbury Nuclear Power Station Reactor vertical dimensions
Scale: 3/8" to 1 ft Size: 77 x 133 Drawing entitled Arrangement of turbo-generator auxiliaries on south side of block. Elevation.
Scale: 1/8" to 1 ft Size: 77 x 133 Drawing entitled General arrangement of pond water and active effluent treatment plant.
Scale: 3/4" to 1 ft Size: 67 x 102 Drawing entitled Sectional arrangement of deaerator and storage tank.
Scale: 1/8" to 1 ft Size: 77 x 133 Drawing entitled General arrangement of reactor unit transverse elevation.
Scale: 1/8" to 1 ft Size: 77 x 133 Drawing entitled General arrangement of pre-irradiated fuel handling equipment
Scale: 1/4" to 1 ft Size: 76 x 111 Drawing entitled Arrangement of reactor coolant pumps and coolers.
Scale: 3/8" to 1 ft Size: 77 x 133 Drawing entitled Arrangement of turbo-generator auxiliaries on south side of block, elevation set 1
Scale: 1/8" to 1 ft Size: 77 x 133 Drawing entitled General arrangement of turbine house transverse section
Scale: 1/4" to 1 ft Size: 77 x 133 Drawing entitled Arrangement of reactor coolant water treatment plant.
Scale: 1/4" to 1 ft Size: 77 x 133 Drawing entitled Arrangement of steam feed pipework from tunnel entrance in turbine house reactor 1
Scale: 1/4" to 1 ft Size: 77 x 133 Drawing entitled Arrangement of steam feed pipework from tunnel entrance in turbine house reactor 1
Scale: 1/4" to 1 ft Size: 77 x 133 Drawing entitled Arrangement of semi-goliath crane for high level deaerator maintenance.
Scale: 1/4" to 1 ft Size: 77 x 133 Drawing entitled Layout of electrical plant in reactor switchgear room 53'-6" level.
Scale: 1/8" to 1 ft Size: 77 x 133 Drawing entitled General arrangement of circulating water. Pump house.
Scale: 1/8" to 1 ft Size: 76 X 111 Drawing entitled Transverse section through services. Block control block & cooling pond. Tender Drawing No. NP/E.5 3.1/4
Scale: 3/8" to 1 ft Size: 77 x 133 Drawing entitled Arrangement of turbine house. Plan between columns 1 & 3.
Scale: 1/8" to 1 ft Size: 77 x 133 Drawing entitled General arrangement fuel handling - plan on operating floor. Tender Drawing No. NP/E.5 3.6/2
Scale: 1/8" to 1 ft Size: 77 x 133 Drawing entitled General arrangement of reactor building, plan. Tender Drg. No. NP/E.5
Scale: 1/8" to 1 ft Size: 77 x 133 Drawing entitled Tender Drg. No. NP/E.5. General arrangement of reactor building. Longitudinal elevation
Scale: 1/2" to 1 ft Size: 77 x 133 Drawing entitled Control block. Cable flat + 46.25' level, Sections from drawing W/C22/575
Scale: 1/2" to 1 ft Size: 77 x 133 Drawing entitled Central control room. Section indicated on Dwg. W/C22/889