Image
Category
Collection
On Display
Object type
Material
Maker
Place
Date
Early submarine cables and grapnel, 1858-1866.

Early submarine cables and grapnel, 1858-1866.

1858-1866

Two shore-end cable samples and telegraph recorder tape, 1926

Two shore-end cable samples and telegraph recorder tape, 1926

1926

Cables

Cables

Cable

Cable

Spare audio connection cable, for communications

Spare audio connection cable, for communications

RCA stereo audio extension cable, for communications

RCA stereo audio extension cable, for communications

Cable sample, coal mining.

Cable sample, coal mining.

Spare audio connection cable, for communications

Spare audio connection cable, for communications

Audio connection cable, for communications

Audio connection cable, for communications

Assorted Cables

Assorted Cables

Cables and mains power supply from IMP 68 computer system

Cables and mains power supply from IMP 68 computer system

Spare audio connection cable, for communications

Spare audio connection cable, for communications

Spare audio connection cable, for communications

Spare audio connection cable, for communications

Spare audio connection cable, for communications

Spare audio connection cable, for communications

Adapter and cables for desktop computer

Adapter and cables for desktop computer

Connecting cables

Connecting cables

Spare audio connection cable, for communications

Spare audio connection cable, for communications

Power supply cables

Power supply cables

Various cables.

Various cables.

Cables and mains power supply from IMP 68 computer system

Cables and mains power supply from IMP 68 computer system

Cables for IBM 286 personal computer

Cables for IBM 286 personal computer

Spare audio connection cable, for communications

Spare audio connection cable, for communications

Bunch of four coaxial cables

Bunch of four coaxial cables

Spare audio connection cable, for communications

Spare audio connection cable, for communications

Vm pc cabling.

Vm pc cabling.

Display board, carrying 32 types of cable used in signalling on British Railways, prepared by Ken Trotman and paul Mustoe, Gloucester ST, November 1993.

display board of signalling cables

1993

132 KV oil filled paper insulated single core cable having 2.0 in hollow stranded aluminium conductor with corrugated aluminium sheathing and PVC outer sheath. Manufactured in 1969

132 KV Oil Filled Paper Insulated Single Core Cable.

1969

275 KV oil filled paper insulated single core cable having 1.0 in hollow segmental stranded copper conductor with corrugated seamless aluminium sheathing and PVC outer sheath. Manufactured in 1969

275 KV oil filled paper insulated single core cable

Cables from da Vinci® Classic surgical system for robot assisted minimally invasive surgery used by Lord Ara Darzi in 2001 to perform the first clinical case using a da Vinci system in the UK, made by Intuitive Surgical, Inc, United States, 1999-2001

Cables, from da Vinci® Classic surgical system

1999-2001

33 KV oil filled paper insulated three core cable having 0.6 in stranded aluminium conductor with corrugated aluminium sheathing and PVC outer sheath. Manufactured in 1969

33 KV oil filled paper insulated three core cable

1969

Set of Interconnecting Cables

Set of Interconnecting Cables

66 KV oil filled paper insulated three core cable having 1.0 in stranded aluminium conductor with reinforced lead sheathing and PVC outer sheath. Manufactured in 1969

66 KV oil filled paper insulated three core cable

1969

Three specimens of paper insulated cables by the British Insulated and Helsby Cables Ltd.

Cross-section of a telephone cable, c. 1900.

1895-1905

1900/3300V PVC insulated three core cable having 0.3 in solid aluminium conductor with bituminised aluminium strip armouring and PVC outer sheath. Manufactured in 1969

1900/3300V PVC insulated three core cable

1969

Connecting cable, (8 of 12), attached to box unit, as used at the Biosignal Laboratory at the Institute of Psychiatry, London, England, established by Professor Hans Eysenck and Dr Paul Barrett to conduct psychological investigations into the relationship between psychophysical and psychometric measures; 1988-1994.

Connecting cable

1988-1994

315 KV oil filled paper insulated single core cable having 0.6 in hollow stranded copper conductor with corrugated aluminium sheathing and polythene outer sheath. Manufactured in 1969

315 KV oil filled paper insulated single core cable

1969

Short samples of four related submarine telegraph cables, mounted on board, together with longer samples of the largest and the smallest of these

Short samples of four related submarine telegraph cables

132 KV oil filled paper insulated three core cable having 0.6 in stranded copper conductor with steel wire armouring and lead alloy sheathing with bronze reinforcement and PVC outer sheath. Manufactured in 1969

133 KV oil filled paper insulated three-core cable

1969

Connecting cable, (2 of 12), attached to box unit, as used at the Biosignal Laboratory at the Institute of Psychiatry, London, England, established by Professor Hans Eysenck and Dr Paul Barrett to conduct psychological investigations into the relationship between psychophysical and psychometric measures; 1988-1994.

Connecting cable

1988-1994

Pallet cables and screws for Bakfiets CargoTrike Classic Wide, used in Berlin from 2015 in fLotte free cargobike hire scheme and its predecessor initiative, Freie Lastenradlern Berlin. Bike is named 'Manni' and was based at Denn's Biomarkt.

Pallet Cables and Screws for Bakfiets CargoTrike Classic Wide 'Manni' used in fLotte Berlin free cargobike hire scheme

circa 2015

25 KV oil filled paper insulated single core cable having 0.85 in stranded aluminium conductor with steel wire armouring and corrugated seamless aluminium sheathing and PVC outer sheath. Manufactured in 1969

25 KV oil-filled paper insulated single core cable

1969

15 KV polythene insulated three core submarine cable having stranded copper conductors with steel wire armouring and polythene sheathing. Manufactured in 1969

15 KV polythene insulated three core submarine cable

1969

22 KV polythene insulated single core screened, water cooled, cable having 1.0 in hollow stranded copper conductor and PVC sheathing. Manufactured in 1969

22 KV polythene insulated single core screened

1969

132 KV oil filled paper insulated single core cable having 0.85 in hollow segmental stranded copper conductor, with lead sheathing and PVC outer sheath. Manufactured in 1969

132 KV oil filled paper insulated single core cable

1969

1100V paper insulated four core cable having 0.4 in solid aluminium conductor with steel tape armouring and lead alloy sheathing. Manufactured in 1969

1100V paper insulated four core cable

1969

Connecting cable, (9 of 12), attached to box unit, as used at the Biosignal Laboratory at the Institute of Psychiatry, London, England, established by Professor Hans Eysenck and Dr Paul Barrett to conduct psychological investigations into the relationship between psychophysical and psychometric measures; 1988-1994.

Connecting cable

1988-1994

Connecting cable, (4 of 12), attached to box unit, as used at the Biosignal Laboratory at the Institute of Psychiatry, London, England, established by Professor Hans Eysenck and Dr Paul Barrett to conduct psychological investigations into the relationship between psychophysical and psychometric measures; 1988-1994.

Connecting cable

1988-1994

660/1100 V Paper insulated five core cable having 4/.3 and 1/.0225 in stranded aluminium conductors with lead sheathing. Steel tape armoured and served. Manufactured in 1969

660/1100 V Paper insulated five core cable

1969

Connecting cable, (5 of 12), attached to box unit, as used at the Biosignal Laboratory at the Institute of Psychiatry, London, England, established by Professor Hans Eysenck and Dr Paul Barrett to conduct psychological investigations into the relationship between psychophysical and psychometric measures; 1988-1994.

Connecting cable

1988-1994

Connecting cable, (10 of 12), attached to box unit, as used at the Biosignal Laboratory at the Institute of Psychiatry, London, England, established by Professor Hans Eysenck and Dr Paul Barrett to conduct psychological investigations into the relationship between psychophysical and psychometric measures; 1988-1994.

Connecting cable

1988-1994